Custom sheet metal manufacturing

Traffic Control Enclosures Built Around Your System

Custom enclosures for smart transportation infrastructure, from intersection signal control cabinets and electronic traffic enforcement systems to roadside monitoring and field automation.

One manufacturing source for cut and formed panels, welded cabinets, inserted hardware, and powder-coated assemblies. Send your drawings or RFQ for a manufacturability review and quotation.

50

Team members

5

Mechanical and manufacturing engineers

6

Full-time QA/QC specialists

Custom traffic control enclosure manufacturing

Enclosure details, materials, and finish are specified and reviewed for each project.

Designed for roadside systems

Protection, ventilation, and service access—planned together

Traffic cabinets protect sensitive electronics in exposed locations. We fabricate to customer drawings and specifications, with project-specific provisions for airflow, rain protection, cabling, mounting, and serviceability.

Natural airflow, rain-aware geometry

Louver layout can be reviewed against airflow needs, cabinet orientation, wind-driven rain exposure, and internal equipment clearances.

Reinforced, project-specific structure

Reinforcements and mounting interfaces can be designed around defined installation conditions, impact loads, and acceptance criteria.

Hardware and service access

Doors, removable panels, hinges, locks, inserts, cable access, and internal mounting provisions follow the project drawing and hardware requirements.

Specialty outdoor finishes

Customer-specified coating systems can address UV exposure, graffiti resistance, or anti-adhesion performance when supported by defined specifications and validation.

Standards and validation: Performance requirements vary by system and jurisdiction. We do not claim compliance with a particular traffic, NEMA, IP, impact, or coating standard unless it has been defined and verified for the project. Include applicable standards and test criteria in your RFQ.

In-house manufacturing

One facility for the main fabrication steps

Our 50-person team includes five mechanical and manufacturing engineers and six QA/QC specialists. In-house production helps reduce fabrication-to-finishing handoffs and coordinates quality across the process.

Process In-house capability Project value
Laser cuttingThree fiber laser machines with 12 kW and 6 kW sourcesAccurate profiles for panels, door openings, vents, and mounting patterns
CNC bendingFive press brakes: two OG35, two OG100, and one OG200Formed panels and structural parts across enclosure sizes and complexity
Hardware insertionAutomated clinching equipment and tapping systemsRepeatable specified PEM nuts, studs, standoffs, and threaded features
Welding24 laser, MIG, TIG, and cold-welding unitsProcess selection based on material, joint design, strength, and visible surfaces
FinishingIn-house preparation, powder coating, and curingA single facility coordinating fabrication and coating
Large-format coatingAutomated powder coating line up to 2500 × 6000 mmSupports oversized cabinets and assemblies within the stated envelope
InspectionSix full-time QA/QC specialistsChecks from incoming material through in-process and pre-shipment inspection

Heavy-duty fabrication tables accommodate assemblies up to 2000 × 6000 mm. Share overall dimensions and assembly breakdown early so handling, welding, and coating feasibility can be confirmed.

Technical design considerations

Ventilation and weather protection start with the requirements

Louver geometry affects airflow, rain ingress, panel strength, and space for internal components. We can fabricate natural-airflow louvers to your drawing or review the proposed layout during DFM. Opening size, orientation, spacing, and internal barriers depend on heat load and environmental criteria.

  • 01Define required airflow or thermal-management criteria.
  • 02Provide cabinet orientation and expected wind-driven rain exposure.
  • 03Share internal component layout, clearances, screens, filters, or rain shields.
  • 04Identify enclosure performance standards and required validation.

We can flag conflicts between openings, bends, welds, hardware, and mounting space. Louvers alone do not establish an ingress-protection rating; environmental performance must be confirmed against your criteria and tests.

Structure and outdoor finish

Durability depends on the complete design: material and thickness, reinforcement, doors and latches, mounting points, welds, installation method, and finish. We can fabricate details to customer drawings, including structures intended for project-defined impact loads.

For UV resistance, anti-graffiti performance, or anti-adhesion coating, specify the coating system, test method, and target performance in the RFQ. These properties depend on selected materials and validation; they are not implied by standard powder coating.

Include coating details

Confirm largest part or assembly dimensions, masking areas, coating thickness, color reference, surface preparation, load cases, test methods, and acceptance criteria.

Engineering before production

A practical DFM review can resolve production questions early

Our five-person engineering team reviews CAD and drawings for sheet metal unfolding, bend allowances, assembly access, and production details before manufacturing.

Still developing your design? Send a 3D model, preliminary layout, or dimensioned concept to discuss manufacturability and clarify missing production information before a purchase order is released.

Bends and clearances

Identify conflicts that could obstruct assembly or service access.

Vent and equipment layout

Check louver locations against equipment, reinforcement, and clearances.

Hardware and tooling

Review positions for insertion access and specified hardware installation.

Welds, finish, and handling

Consider visible surfaces, dimensional control, part size, coating, and assembly divisions.

Applications and production scope

Choose a process that fits the traffic system

We support high-mix, low-to-medium production, with typical batches of 10 to 500 units as well as recurring supply programs.

Signal-light master control cabinets

Provide controller dimensions, cable-entry locations, mounting patterns, ventilation needs, and door-access requirements.

Electronic traffic enforcement systems

Include camera, communications, and power interfaces, plus project-defined structural and surface-finish criteria.

Roadside monitoring and smart traffic

Specify equipment heat load, exposure conditions, service intervals, and the required balance between airflow and weather protection.

Large-format equipment housings

Share assembly dimensions early. The 2500 × 6000 mm coating line and 6-meter fabrication platforms may support large assemblies, subject to geometry and handling review.

For prototypes and low-to-medium volumes, early drawing review can prevent repeated design issues across a batch. For recurring orders, an agreed drawing revision, material specification, finish, and inspection plan help maintain consistency between production runs.

Prepare your RFQ

Specifications that help us quote accurately

A complete package makes it easier to select processes, quote the right scope, and identify technical questions before production.

RFQ detailInformation to provide
Product and applicationSignal controller, enforcement system, roadside monitor, or other use
Drawings and material2D manufacturing drawings, 3D CAD if available, material grade, thickness, and required certifications
Dimensions and ventilationCabinet envelope, part sizes, assembly breakdown, louver layout, airflow criteria, rain protection, screens, or filters
Structure and hardwareMounting method, reinforcement, defined impact loads and tests, hinges, locks, inserts, studs, and gaskets
Finish and complianceColor, coating specification, surface preparation, UV or graffiti test requirements, standards, inspections, and validation documents
Commercial scopePrototype or production quantity, annual forecast, packaging, delivery destination, and target schedule

If compliance testing, coating validation, or special inspection is required, state it at RFQ stage so scope and responsibility can be agreed before production.

Start a project review

Request a traffic enclosure quote

Send your drawings, quantity, material, finish requirements, and target delivery schedule. Our team can review the package, identify missing specifications, and prepare a quotation.

For a first inquiry, include the application, cabinet dimensions, required standards or test criteria, and whether you need a prototype, production batch, or recurring supply.

Enclosuremfg

Company address: Building 4, Kuiqing Road, Qingxi Town, Dongguan City, Guangdong Province

Email: info@enclosuremfg.com

Share your project details

Attach the available drawings and identify any open specifications for review.